Watts & Febco RPZ Backflow Preventers, Rubber Repair Kits, Apollo, Jenkins & Kunkle Valves

Pass Massachusetts DEP 310 CMR 22.22 municipal cross-connection surveys and keep high-pressure steam, air, gas, and process headers leak-free with counter-stocked backflow assemblies, factory rubber kits, and industrial valves.

Backflow Preventers & Kits Watts (North Andover, MA — 009, 909, 007, 9D, LF009), Febco (825Y, 860, 765) & Zurn Wilkins • 1/2" to 4"+
Industrial Ball & Butterfly Valves Conbraco / Apollo (70/77/82/88 Series), Watts, Webstone, Nibco, Hammond, Milwaukee & Victaulic
Steam, Gate, Globe & Check Valves Jenkins Valves (Class 125/150/200/300 Bronze & Cast Iron), Stockham, Kennedy & Powell
Safety Relief & Solenoid Valves Kunkle Valve (ASME Section I & VIII Steam/Air), Watts/Conbraco Section IV & ASCO RedHat Solenoids
Lowell Trade Counter Engineering Reference • Est. June 18, 1927

Backflow Cross-Connection Compliance & Heavy Industrial Valve Supply

Under Massachusetts DEP Cross-Connection Control regulations (310 CMR 22.22), Reduced Pressure Zone (RPZ) backflow preventers must be tested semi-annually and Double Check Valve Assemblies (DCVAs) annually by a certified backflow tester. When a relief valve dumps water or a #1 check fouls with pipe scale during an inspection, you need the exact factory rubber repair kit or lead-free replacement assembly immediately.

Founded just miles from Watts Regulator's historic Merrimack Valley roots, Frank P. McCartin Co., Inc. stocks Watts and Febco backflow preventers, total rubber repair kits, check modules, and test cocks alongside Conbraco/Apollo bronze, carbon steel, and stainless ball valves, Jenkins steam globe/gate/check valves, Kunkle ASME safety valves, and ASCO RedHat solenoid valves.

Direct Counter Dispatch

Need Immediate Part Verification?

Bring your sample component or email a clear nameplate photo to our 149 Congress Street counter team for same-day pickup or regional truck delivery.

Electrical/Electronics: (978) 454-9101 • ELE@
Plumbing/Steam/Boilers: (978) 454-7606 • PVF@
Finance/Tax-Exempt: (978) 453-1681 • ar@
Engineering Cross-Reference Matrix 01

Watts & Febco Backflow Preventer & Factory Repair Kit Matrix

Stocked at 149 Congress St for municipal water departments, mechanical contractors, and certified backflow testers.

Model SeriesDevice Type & Hazard ClassSize RangeGenuine Repair Kits StockedCommon Failure / Service Fix
Watts LF009 / 009 (M1, M2, M3)Reduced Pressure Zone (RPZ) — High Hazard1/2" to 3"Total Rubber Kit (RK-009-RT), 1st/2nd Check Kits & Relief Valve Kit (RK-009-VT)Note series suffix (M1 vs. M2 vs. M3 on 3/4"–2" models!) before ordering check seats or rubbers
Watts LF909 / 909High-Capacity RPZ — Boiler & Plant Mains3/4" to 10"1st/2nd Check Discs, Relief Valve Piston/Diaphragm & Air-Gap Drains (909-AG)Fouled relief sensing passage or torn diaphragm causing continuous relief port discharge
Watts 9D / LF9DDual Check with Atmospheric Vent — Residential/Light Commercial Boiler Feed1/2" & 3/4"Complete Lead-Free LF9D-M3 / LF9D-M2 AssembliesReplace complete body when atmospheric vent port drips during boiler make-up fill
Febco 825Y / LF825Y & 860Reduced Pressure Zone (RPZ) — High Hazard3/4" to 2"Complete Rubber Kit (FRK-825Y-RT / FRK-860-RT), Check Poppets & Relief StemWorn silicone check disc or relief diaphragm from fluctuating municipal street pressure
Febco 765 (PVB)Pressure Vacuum Breaker — Commercial Irrigation1/2" to 2"Bonnet & Poppet Kit (FRK-765-BP) + Check Valve KitFreeze-cracked plastic bonnet/poppet after early autumn frost—can be rebuilt quickly in the field
Specification & Replacement Matrix 02

Industrial Steam, Process, Safety Relief & Solenoid Valve Reference

Engineered for saturated steam, compressed air, natural gas, glycol, and chemical process piping.

Valve FamilyStocked ManufacturersPressure / Class RatingsEngineering & Seat Specifications
Industrial Bronze & Steel Ball ValvesConbraco / Apollo (70-100, 70-600, 82-100, 89-100)600 WOG / 150 WSP (Up to 2000 WOG Carbon/SS)RPTFE (Reinforced Teflon) seats, blowout-proof stems, adjustable packing gland & steam-trim options
Steam Globe, Gate & Swing Check ValvesJenkins Valves, Stockham, Hammond, MilwaukeeClass 125, Class 150, Class 200 & Class 300 WSPRenewable bronze, PTFE, or hardened stainless-steel plug/cone seats for throttling steam headers
ASME Section I, IV & VIII Relief ValvesKunkle Valve, Conbraco/Apollo, Watts5 PSIG to 300+ PSIG (Steam, Air & Liquid)Factory set-and-sealed ASME 'V' (Heating Steam), 'HV' (Hot Water) & 'UV' (Unfired Pressure Vessel / High-Pressure Steam)
2-Way & 3-Way Solenoid ValvesASCO RedHat (8210, 8262, 8040 Gas), Sporlan0 to 300 PSI • 24VAC, 120VAC, 240VAC, 12/24VDCDirect-acting and pilot-operated brass/stainless bodies with Buna-N, EPDM (steam/hot water), or Viton elastomers
Lowell Trade Counter Field Protocol

Counter Ordering Checklist for Backflow Kits & Industrial Valves

  • For Watts 009 Backflow Kits: Always check the cast-in suffix on the bronze body (`009` vs. `009M1` vs. `009M2` vs. `009M3`). A 3/4" `009M2` uses different check retainer geometry than a `009M3`!
  • For Kunkle / Apollo Safety Relief Valves: Specify the required ASME Stamp (`V` for low-pressure steam at 15 PSI, `HV` for hot water boilers, or `UV` for high-pressure steam/air compressors), inlet x outlet NPT size, set pressure (PSIG), and required BTU/hr or lbs/hr discharge capacity.
  • For ASCO RedHat Solenoid Valves: Record the full catalog number (e.g., `8210G002`), coil voltage, pipe size, normally-closed vs. normally-open operation, and fluid temperature.
Frequently Asked Engineering Questions

Counter Q&A: Watts & Febco Backflow, Apollo, Jenkins & Kunkle Valves

Why is water discharging intermittently from the bottom relief port of our Watts 009 RPZ backflow preventer?

Intermittent spitting from an RPZ relief valve is most commonly caused by pipe scale or debris lodged under the #1 Check Valve seat (allowing upstream pressure spikes to drop the differential across the #1 check below ~2–3 PSI) or a worn relief valve diaphragm. Cleaning the #1 check and installing a genuine Watts RK-009-RT total rubber kit resolves the issue in over 90% of inspections.

Can I use a standard 600 WOG brass ball valve on a 50 PSI steam line?

Only if its seat and stem packing are rated for saturated steam at that temperature (50 PSIG steam is 298°F). Standard virgin PTFE seats cold-flow under cyclic steam service; for steam lines, we supply Apollo 70-100 / 70-600 series bronze ball valves with MPTFE/RPTFE steam-rated seats or Jenkins Class 150/200 bronze globe and gate valves.

Do you carry replacement RedHat coils and rebuild kits for ASCO solenoid valves?

Yes. We stock and cross-reference ASCO 8210, 8262, and 8040 series solenoid valves, replacement RedHat / RedHat II encapsulated coils (24V, 120V, 240V), and internal diaphragm/core rebuild kits.

149 CONGRESS ST, LOWELL, MA • TRADE COUNTER & MUNICIPAL DESK COMMBUYS #201354 • MHEC G14 / G19

Request a Counter Quote or Cross-Reference: Watts & Febco Backflow, Apollo, Jenkins & Kunkle Valves

Routed directly to our 149 Congress Street, Lowell specialists. Eligible for COMMBUYS FAC124 (#201354) and MHEC G14 (#374) / G19 (#419) purchasing.

Direct Counter Routing (Mon–Fri 7:00 AM – 4:00 PM) •
CALL (800) 929-9101